9V Battery Dimensions, Size & Codes

The catalog envelope is 26.5 mm wide × 17.5 mm deep × 48.5 mm high. These are the maximum envelope values in the cited Energizer 522 drawing, not a measurement of every 9V product. Check the exact battery and compartment before replacing it.

Technical content reviewed 2026-09-08

6LR61PP3MN16041604A
Nominal voltage
9 V
Dimensions
26.5 × 17.5 × 48.5 mm
Chemistry
Alkaline manganese dioxide

9V dimensions by manufacturer: maximum is not approximate

These are manufacturer-published alkaline 9V examples, not our measurements. Dimensions below use width × depth × overall height in millimetres; the source pages use different axis orders. Preserve the complete model and the source’s dimension convention.

Three product references, checked October 25, 2026
Manufacturer / productW × D × H (mm)What the source actually specifiesContact evidence
Energizer 522 · 9.0 V alkaline26.50 × 17.50 × 48.50 maximumDrawing ranges: width 24.50–26.50; depth 15.50–17.50; overall height 46.50–48.50. Body-only maximum 46.40 excludes the projecting terminals.Miniature snap; use the drawing for contact geometry.
Panasonic EVOLTA 6LR61EJ/1S · body 6LR61Y(EJ) · 9 V alkalineApproximately 26.5 × 17.5 × 48.5The Japanese specification uses approximately (約), not an explicit minimum/maximum tolerance.No terminal drawing on this cited specification page.
FDK 6LR61 · 9 V alkaline26.5 × 17.5 × 48.5 maximumThe table labels these maximum sizes (最大値). Lower limits are not supplied there.No contact dimensions in that size table.

Equal listed numbers do not establish the same tolerance, connector clearance or approved substitution. This table covers primary alkaline examples only. Continue to the separate rechargeable 6HR61 profile or size finder; the device’s required chemistry and polarity still control the decision.

Check the body, snap terminals and compartment separately

The Energizer 522 drawing (Form 522GL1019) identifies a 9.0 V alkaline product with miniature snap terminals. Use its dimensioned drawing for that product; a matching outer envelope alone does not establish connector fit, chemistry approval or clearance for leads.

  1. Record the full manufacturer, model and printed chemistry of the old and proposed batteries.
  2. Compare width, depth and overall height with the manufacturer drawing and the available compartment, including the connector and cable space.
  3. Check polarity and the equipment manual. Do not force the connector or treat a rechargeable lookalike as an approved replacement.

The dimensions above come from the manufacturer drawing cited here. Review the separate 6HR61 rechargeable profile before considering a different chemistry.

9V specifications

Canonical code9V
Formrectangular
RechargeableNo
Drain markingNot specified

Typical applications

  • Household electronics
  • lights
  • remotes
  • portable devices

Replacement decision

Resolve the original marking to this profile, then confirm nominal voltage, chemistry, dimensions, polarity and any drain or terminal suffix. Capacity alone does not establish interchangeability.

Exact equivalents and aliases

The catalog 9V profile is a 9 V alkaline rectangular battery. The printed 6LR61, PP3, MN1604 and 1604A markings resolve to that same profile; the 6HR61 profile uses the VIDEX 6HR61/300/1DB/8.4V manufacturer example, rated 8.4 V NiMH. Its nominal envelope matches the listed format; actual fit and device approval remain separate.

6LR61, PP3, MN1604 and 1604A are reviewed aliases of the canonical 9V profile. They are different markings for the same catalog row, not four extra battery sizes.

MarkingCatalog profileVoltageChemistryDimensionsDecision
9V / 6LR61 / PP3 / MN1604 / 1604A9V · Alkaline9 VAlkaline manganese dioxide26.5 × 17.5 × 48.5 mmExact alias / canonical profile
Resolves to 9V; verify polarity and the device marking.
  • Canonical code and reviewed aliases resolve to one profile.
6HR616HR61 · NiMH8.4 V (VIDEX example)Nickel-metal hydride26.5 × 17.5 × 48.5 mmSame size · different voltage
Use the exact voltage and battery system specified by the device manufacturer.
  • The nominal format matches; check actual manufacturer tolerances and the holder.
  • Nominal voltage differs: 9 V versus 8.4 V (VIDEX example).
  • Chemistry also changes from Alkaline manganese dioxide to Nickel-metal hydride.

Conditional substitutes

6HR61 is not a direct replacement for the 9 V alkaline profile. The cited VIDEX example is rated 8.4 V NiMH; that rating does not cover every 6HR61 or 9V NiMH pack. Verify the exact manufacturer, rating, device instructions and approved charger; matching nominal dimensions grants no fit or substitution approval.

Physical fit is not electrical compatibility

A rectangular case can fit the compartment while the voltage and charging requirements remain wrong. Check the snap-terminal arrangement and the device manual before installing any battery that is not an exact alias.

How to verify before replacing 9V

  1. Read the full marking, including 6LR61, PP3, MN1604 or 1604A.
  2. Confirm the device calls for a 9 V primary battery, not a rechargeable pack.
  3. Match the listed dimensions and terminal arrangement; physical entry alone is not an electrical approval.

Continue with: Compare the household AAA profile Read about rechargeable lookalikes Measure the battery envelope

Same-size batteries to review carefully

These profiles share the nominal physical envelope. They are not automatically equivalent.

Reviewed comparisons

Technical sources

  1. International Electrotechnical Commission — IEC 60086-1:2026 — Primary batteries, general requirements

    Primary-battery nomenclature, form, fit, function, terminal and electrochemical-system framework.

  2. Energizer — Battery Replacement Guide

    Cross-reference codes and manufacturer guidance to replace the same size and type together.

  3. Duracell — Battery Cross Reference Chart

    Independent manufacturer cross-reference families and corresponding product numbers.

  4. Duracell — Battery chemistry technical bulletins

    Alkaline, lithium-manganese-dioxide, zinc-air and silver-oxide chemistry behavior.

Replacement card: 9V and the catalog 6HR61 profile

An original desk exercise, not a device test. Keep three decisions separate: identity, physical envelope and permission to install.

Observe / documentInterpretationNext check
Original marking: 6LR61 / 522Catalog primary alkaline profile: 9.0 VCopy the full device manual requirement.
Candidate: VIDEX 6HR61/300/1DB/8.4V; EAN 4820118294797Manufacturer example: 8.4 V NiMH; listed body 26.5 × 17.5 × 48.5 mmDevice/charger permission and terminal fit remain unresolved; this is not a universal 6HR61 rating.
Two snap contactsA matching connector does not resolve the voltage or charging systemDo not charge a primary battery; follow the product and device instructions.

Limit: The 8.4 V value belongs only to the cited VIDEX product. Other packs sold as 6HR61 or 9V NiMH require their own manufacturer rating, device and approved-charger checks. This card grants no fit or substitution approval.

Sources and scope for this exercise

Compare the catalog profiles · Review fit versus approval

Read a capacity curve without inventing runtime

Annotated reading of the capacity-versus-current bar chart in Energizer 522, Form 522GL1019. The source also contains application discharge curves with different schedules; keep them separate.

Read a capacity curve without inventing runtime — original schematic, not a photograph
Original schematic; not life-size. Read the comparison table for the observable differences.
Observe / documentInterpretationNext check
522 capacity bar chart: 10 / 25 / 50 mA continuous drainVisual readings: approximately 600 / 500–600 / 400–500 mAh, respectivelyThese are coarse readings from the published chart, not new measurements or device runtime.
Test boundaryContinuous discharge at 21 °C to 4.8 VA different cutoff, load or temperature is a different comparison.
Application examples on the sheetDifferent schedules use different loadsDo not carry the radio result into a smoke-detector or other device claim.

Limit: No runtime estimate is supplied. Keep current, temperature, cutoff and schedule with any number copied from a curve.

Sources and scope for this exercise

Read a datasheet